Digital storage oscilloscope pdf

Digital storage oscilloscope pdf

These scopes may be referred to as digital oscilloscope or digital storage oscilloscope. Although these two names used to indicate separate types of instrument, they are often used interchangeably. Analogue storage scopes were not particularly effective, and therefore there was a need for effective storage technologies.

The original digital storage scopes had analogue input stages, and then converted the signals into a digital format to enable them to be stored in digital memory.

They could then be processed before being converted back into an analogue format for display on a cathode ray tube. As technology progressed, the storage facility was retained, but the whole scope became digital. For a while, there was a difference between standard digital scopes and those with a storage capability, but this difference was gradually overcame as the facility became incorporated on all digital oscilloscopes. Accordingly the two types are effectively the same, and the names are often used interchangeably to describe the same type of test instrument.

What is a Digital Storage Oscilloscope ?

When the signal enters the scope it is first pre-conditioned by some analogue circuits to ensure that the optimum signal is presented to the next stage. The rate at which samples are taken is often defined as part of the specification of the scope. This is measured in samples per second, and often quoted in Mega samples per second M samples per second.

The samples from the ADC are then stored in memory and referred to as waveform points and together these points make up the overall waveform record. The number of waveform points within the record is referred to as the waveform length. The waveform record is initiated by the trigger and again stopped by the timebase circuit after the given amount of time. The waveform record is then processed by the processing circuitry and presented to the display for visual inspection by the user.

I am Sasmita. At ElectronicsPost. And, if you really want to know more about me, please visit my "About" Page. Read More. Sasmita Hi!DS is a 2-channel digital oscilloscope. It is in a new design - two gear for controlling, very convenient for testing. It is widely applicable in the academic experiment, electronic maintenance, electronic engineering tasks, etc. This is a terrific little tool for testing small electronics on the go. The build quality on the unit is solid.

The signal generator is a nice bonus feature. The menus are easy to navigate. The downside is that it is only 1mhz. I would pay extra for 25mhz model, for sure. However - I have measured signals up to 3. The 1x probe is a little cheap, and the male pin in the BNC connector broke on the first day, but replacement probe are cheap and constructed with far more care.

I was skeptical of this device, but after using it for a few weeks, I am very pleased with the unit.

Digital Oscilloscope & digital storage oscilloscope, DSO

I can't really complain. This is not a full blown replacement for a table-top device and I knew that before I bought it. Yes, it's way of controlling the different settings is. It's small, but the screen is well readable. I am using it for audio device repairs and that works quite well. So you might not be able to read the signal coming from your turntable cartridge.

I am using a step-up-transformer to read very low signals, but YMMW. This tiny O-scope is handy if you have a portable bench. To get more use out of it I recommend adding some velcro to keep it held in a larger travel case. It's so small that it slides around when you move the probes. I got the two channel model, which I recommend. The first one received quit working after about two hours and was promptly replaced with a new DSO. Good customer service!!! The scope has lots of nice features that are mainly found in bench type scopes.

I use it for audio performance test and it works great. It would be easier to work with if the probes used BNC as the small jacks tend to slip out.

The thumb wheels work ok but its hard to push the switch without turning the wheel. I would buy it again.These analog storage oscilloscopes were very expensive and as a result they were generally only used for specialist applications.

How to use an oscilloscope / What is an oscilloscope / Oscilloscope tutorial

The analog storage oscilloscope provided the capability for displays that would normally only persist for a fraction of a second could be stored for possibly several minutes. By the standards of todays digital oscilloscopes that can easily store waveforms, these analogue storage oscilloscopes were very crude in terms of their performance, and despite this they were very expensive.

However they were the only way in which displays could be stored for longer than the natural persistence of the cathode ray tube screen. For these and many other situations, it is necessary to have a storage facility on the scope where it can display the trace for longer than would normally be possible. Analogue storage scopes use a special cathode ray tube with a long persistence facility. A special tube with an arrangement to store charge in the area of the display where the electron beam had struck, thereby enabling the fluorescence to remain for much longer than attainable on normal displays.

These cathode ray tubes had the facility to vary the persistence, although if very bright traces were held over long periods of time, they would have the possibility of permanently burning the trace onto the screen. Accordingly these storage displays needed to be used with care. In terms of the actual analogue storage oscilloscope technology, the special cathode ray tubes used rely on a technique called secondary emission. The storage capability utilises the fact that using the ordinary writing electron beam not only causes the phosphor to illuminate, but the kinetic energy of the electron beam also knocks other electrons loose from the phosphor surface - this is the secondary emission process.

When electrons have been freed from the surface of the illuminating phosphor they leave a net positive charge in that region. This fact is used by analogue storage oscilloscopes as their cathode ray tubes contain one or more secondary electron guns, or "flood guns. Flood guns electrons are emitted in such a way that they cover the entire screen in as uniform a manner as possible.

digital storage oscilloscope pdf

When they travel along the tube, the electrons from the flood guns are more strongly drawn to the areas where there is a positive charge as dissimilar potentials attract. According the areas of the phosphor screen where the writing gun has left a net positive charge attracts more electrons and as a result the illuminating electrons from the flood guns re-illuminate the phosphor in the positively charged areas of the phosphor, i.

It is necessary to ensure that the electrons from the flood guns have just sufficient energy to release one electron from the screen. In this way the positive charge is preserved in the area and the pattern on the screen remains.

As can be imagined, the system is far from perfect, and over time the stored image becomes blurred and less distinct. Nevertheless the storage capability enables the waveform to be displayed on the screen for much longer than would otherwise become possible.

Analogue scope applications Analogue storage oscilloscopes were needed in a variety of different applications. It must be remembered that time a display remained visible after a scan was relatively short. The cathode ray tube operation normally relied on the repeated refresh of the screen as the scan was repeated many times a second. Thus the normal persistence of a display would mean that the trace for a long period waveform would decay before it was complete.

Example of an analogue storage oscilloscope For these and many other situations, it is necessary to have a storage facility on the scope where it can display the trace for longer than would normally be possible.

Analogue oscilloscope technology Analogue storage scopes use a special cathode ray tube with a long persistence facility. Return to Oscilloscope Types page. Supplier Directory For everything from distribution to test equipment, components and more, our directory covers it. Selected Video What is an Oscilloscope - tutorial. Featured articles.An oscilloscopepreviously called an oscillograph[1] [2] and informally known as a scope or o-scopeCRO for cathode-ray oscilloscopeor DSO for the more modern digital storage oscilloscopeis a type of electronic test instrument that graphically displays varying signal voltagesusually as a two-dimensional plot of one or more signals as a function of time.

Other signals such as sound or vibration can be converted to voltages and displayed. Oscilloscopes display the change of an electrical signal over time, with voltage and time as the Y- and X-axes, respectively, on a calibrated scale.

The waveform can then be analyzed for properties such as amplitudefrequencyrise timetime interval, distortionand others. Modern digital instruments may calculate and display these properties directly. Originally, calculation of these values required manually measuring the waveform against the scales built into the screen of the instrument.

The oscilloscope can be adjusted so that repetitive signals can be observed as a continuous shape on the screen. A storage oscilloscope can capture a single event and display it continuously, so the user can observe events that would otherwise appear too briefly to see directly.

Oscilloscopes are used in the sciences, medicine, engineering, automotive and the telecommunications industry. General-purpose instruments are used for maintenance of electronic equipment and laboratory work. Special-purpose oscilloscopes may be used for such purposes as analyzing an automotive ignition system or to display the waveform of the heartbeat as an electrocardiogram.

Early oscilloscopes used cathode ray tubes CRTs as their display element hence they were commonly referred to as CROs and linear amplifiers for signal processing. Storage oscilloscopes used special storage CRTs to maintain a steady display of a single brief signal.

CROs were later largely superseded by digital storage oscilloscopes DSOs with thin panel displaysfast analog-to-digital converters and digital signal processors. DSOs without integrated displays sometimes known as digitisers are available at lower cost and use a general-purpose digital computer to process and display waveforms. The Braun tube was known inand in Jonathan Zenneck equipped it with beam-forming plates and a magnetic field for sweeping the trace.

Zworykin described a permanently sealed, high-vacuum cathode ray tube with a thermionic emitter in This stable and reproducible component allowed General Radio to manufacture an oscilloscope that was usable outside a laboratory setting. The basic oscilloscope, as shown in the illustration, is typically divided into four sections: the display, vertical controls, horizontal controls and trigger controls.

The display is usually a CRT historically or LCD panel laid out with horizontal and vertical reference lines called the graticule. CRT displays also have controls for focus, intensity, and beam finder. The vertical section controls the amplitude of the displayed signal.To browse Academia.

Skip to main content. Log In Sign Up. Andrei Purcarus. This oscilloscope which will theoretically allow us to perfectly reconstruct band- is capable of capturing a waveform using an ADC, processing it in real-time and displaying it on a VGA monitor. It also uses an internal frequency counter to measure the applying a low-pass filter on the resulting waveform, which trigger frequency of waveforms with at most 0.

In addition, it provides measurements of the peak-peak, average, max and sampled points [5]. This frequency was chosen to account for practical 4. Potential improvements and additions to the functionality limitations in the interpolation algorithm. Since an ideal low- of the oscilloscope are also discussed. We will also aim for a minimum frequency of 1 kHz, which I. This will allow for multiple waveform captures over a single frame, and hence allow us to perform processing in real time.

This serves as a proxy since this board contains the necessary hardware peripherals for the waveform frequency, and will correctly identify it for to implement an oscilloscope.

We will compare the accuracy of this measurement bit video DAC connected to a VGA D-Sub connector [1], to the frequency measurement accuracy obtained by previous [2]. The resolution of our frequency measurement will input waveform and the video DAC to display the processed be limited by the clock rate, and we will therefore aim for an waveform on a VGA monitor.

We operations such as the FFT [3]. We aim to eliminate this aim to produce peak-peak, average, max and min voltage bottleneck by providing a pipelined, parallel implementation measurements for the captured waveforms. Given that we have of the DSO functionality. It is here that interpolation by a predefined event. This event usually consists of the will really be tested since for higher frequencies the limited input waveform crossing a certain reference level with a sampling rate means that we might not be able to capture the positive or negative slope, referred to as rising edge and falling peaks of the waveform through the ADC.

Hence we will rely edge triggering, respectively [3]. It is necessary to have this on interpolation to produce these values, and compare them trigger for a stable waveform display, as it centers a periodic to the actual values. For evaluation, the project will first be simulated using an Although DSOs have been implemented on FPGAs before analog waveform generator designed in a previous assignment as student projects, the lack of proper interpolation led to a for this course.

Then, the project will be synthesized on allowing the modules to process complete waveform data. This the FPGA board and analog signals from a signal generator avoids the issue of one module overwriting the data while will be fed to the ADC and compared to the readouts on a another is reading it and corrupting the waveform.

We now commercial oscilloscope and multimeter. A block diagram of the module is shown in Figure 2. Simplified top-level block diagram of the DSO. A simplified block diagram of the DSO is shown in Figure 1. The analog waveform we wish to capture is assumed to have been processed by external analog circuitry and sampled by an ADC.

Block diagram of the VGA driver module. This ADC signal is monitored by a triggering module which produces a trigger signal on a rising or falling edge of the The VGA timing generator entity is used to produce the input waveform. When triggered, it waits the on-screen data when outside of the visible area.

In order to allow for vertical interpolation between this memory block, processes it, and burst writes it to a second consecutive data points, it also outputs the subsequent data memory block. A trigger correction module then burst reads point. If no such data point exists, it outputs the same data the data from this second memory block and attempts to point twice.The levels of accuracy are higher, displays are cleared, and there are a shot of advantages to using digital scopes.

As a result of the storage capability, many digital oscilloscopes may also be referred to as a digital storage oscilloscope, DSO. Digital oscilloscopes have taken over virtually completely from their analogue cousins. It is now difficult to buy new analogue scopes - the only ones that are available today are digital.

Fortunately entry level digital oscilloscopes can be obtained for very reasonable provides and at the performance end of the market, the levels that can be achieved are exceedingly high.

Signals can enter the scope as analogue signals but they are converted into a digital format and this enables the power of the signal processing techniques that are available to provide much greater levels of functionality and this enables better insight into the signals that can be monitored.

The samples from the ADC are stored in memory and referred to as waveform points and together these points make up the overall waveform record. The number of waveform points within the record is referred to as the waveform length.

The times and rate at which samples are taken is determined by the system clock. The rate at which samples are taken is often defined as part of the specification of the scope. In addition to this, the resolution of the analogue to digital converter is important. The higher the number of bits from the ADC, the greater the accuracy with which the waveform is sampled.

Typically very low resolution scopes may only have an 8 bit ADC and this can result in steps being seen not he displayed waveform as the level of the waveform moves up or down by one bit. Scopes typically have a greater resolution with scopes having 10, 12 and even up to 16 bit ADC resolution levels. The higher the resolution, the greater the details hat can be seen, especially as the scope is zoomed in on a vertical portion of a waveform.

Although microprocessors can be used to form the heart of the signal processing in the digital scope, it is more normal to use FPGS or sometimes CPLDs. These chips can be programmed to perform exactly the forms of manipulation that are required, and often in a parallel manner. This enables much higher levels of performance to be achieved. When signals enter the digital oscilloscope, they pass through an analogue conditioning stage.

The resulting waveform is then passed to the analogue to digital converter, ADC. The ADC may have one or many cores - if it has multiple cores then the data is typically streamed in parallel to the FPGA and into memory. With data stored in this way, it is possible to process it in a variety of ways, recalling the data from memory as required.

Many digital oscilloscopes offer a logic analysis capability and incorporate some or digital input channels. These do not require the same analogue processing and they can be passed directly into the FPGA, obviously via protection circuitry. Scopes with this capability are typically referred to as MSOs or mixed signal oscilloscopes. Essentially ice the waveform is stored in memory, the trigger can be adjusted to trigger on any point onto e waveform - the trigger point can even be int he centre of the screen allowing the waveform before and after the trigger point to be viewed.

digital storage oscilloscope pdf

Another advantage is that analogue triggering has a certain hysteresis within the system. This needs to be incorporated to ensure that the waveform is triggered at the correct point. Using digital techniques a much more accurate trigger can be obtained enabling the display to be much clearer even into e presence of noise.

Also the trigger can be fired in a variety of other ways, even on a specific series waveform, etc.HantekL LA discontinued. HT - Process Calibrator. Project Development Secondary Development Service. DSOC Series. DSOB Series. MSOD Series. DSOP Series. Product Registration After-sales service Questions. Product Category.

The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously. Overview Parameters Comparison Accessories Download. For non-sinusoidal waveforms, peak value must be less than V. Excursion above V should be of less than ms duration. If these values are exceeded, damage to the oscilloscope may occur. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.

Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.

digital storage oscilloscope pdf

Less than: The trigger point is the trailing edge. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.

Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work.

digital storage oscilloscope pdf

Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Greater than also called overtime trigger : The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.